product details / scope of delivery
- Emission tester stands out due to limited weight and compact design
 - Short warm-up time, quick measurement readiness
 - Accurate analysis of gas components HC, CO, CO2, O2 with lambda value calculation
 - Intuitive operation, clearstructure in emissions testing process as set out in current guidelines 5 enable minimum cycle times
 - Varied and simple network connection options LAN / WLAN (optional)
 - The MAHA VCI makes EOBD analysis easy
 - Innovative method for separation of condensed water thanks to active water separator
 - MID type approval
 - Emission testing of CNG, LPG and petrol engines possible
 - Options:
- W-LAN interface
 
 
Scope of delivery:
- Basic device (gas analyser) in high-quality synthetic casing with integrated display unit and keypad
 - Steel mesh emission probe, 600 mm, probe tubing 8 m
 - LAN interface with LAN cable
 - Power supply unit 110V - 230V, 50/60Hz
 - Transparent drain hose for condensed water withcollecting tank
 - Main filter, zero filter and condensate filter
 - Electrochemical O2 sensor
 - Trigger tongs for MET 6.1 and 6.3 for inductive RPM measurement at ignition cables
 - 2 replacement filters, 2 replacement seals
 - Measurement software for continuous measurement without country-specific test procedure
 
Technical Data
Technical Data:
| Measurement principle: | |
| infrared spectrometry | HC, CO, CO2 | 
| Measurable gases | HC, CO, CO2, O2 | 
| Electrochemical detection | O2 | 
| Flow rate | 3.5 l/min | 
| Operating conditions: | |
| Temperature | 0°C to 45°C | 
| Height | -100 m to +3000 m | 
| Power supply | 110-230V 50/60 Hz | 
| On-board voltage connection | 10-30 V, DC | 
| Accuracy class | 0 (OIML) | 
| Dimensions (L x W x H) | 406 x 225 x 160 mm | 
| Weight | approx. 4.6 kg | 
| Measurement range / measured value resolution (max.): | |
| CO | 0-15 % Vol. / 0.01 | 
| CO2 | 0-20 % Vol. / 0.01 | 
| HC | 0-9999 ppm / 0.1 | 
| O2 | 0-25 % Vol. / 0.01 | 
| Lambda (calculated) | 0.5-9.99 / 0.01 |